Service Hotline008615767831427
中文Your location:Home > Product > Ultrasonic Heat Meter
Type:Ultrasonic Heat Meter
Service Hotline:008615767831427
Without any mechanical movement, no wear and tear, not affected by poor water quality, low maintenance costs.
The use of imported high-quality transducers ensures the high accuracy and stability of the flow measurement.
Low initial flow.
Can
be installed in horizontal and vertical direction, the rotation of the
header to meet the reading requirements in different directions.
Pulse, M-BUS bus and RS485 bus output interface enables remote data, centralized control.
Automatic error diagnosis to ensure safe and accurate operation.
Hot and cold dual (heating, cooling can be measured).
Optional back and forth water temperature to facilitate the construction and installation.
Battery life of 6 years.
DN15--DN40 Technical data
Nominal diameter (DN)
15
20
25
32
40
Nominal flow (m³ / h)
1.5
2.5
3.5
6
10
Flow m³ / h)
3
5
7
12
20
Flow rate (m³ / h)
0.03
0.05
0.07
0.12
0.2
level of accuracy
Level 2, Level 3
Pressure loss
<25kpa
Nominal pressure
1.6Mpa
Connection method
Thread
Temperature sensor type
PT1000 Platinum resistance
Temperature measurement range
(4~95)℃
Temperature range
(3~90)℃
Temperature resolution
0.01℃
Ambient temperature
A class+5~+55℃
Battery Life
≥6years
medium
Cold or hot water
Display digits
8 bits
DN15 - DN40 Dimensions
Nominal diameter (DN)
15mm
20mm
25mm
32mm
40mm
Flow sensor length (mm)
130
130
130
180
200
Flow Sensor Interface Thread (inch)
G3/4B
G1B
G11/4B
G11/2B
G2B
With take over length (mm)
224
234
250
304
348